Seitenhistorie
...
Terminologie Assoziation:
| Code | BEZEICHNUNG IM CODESYSTEM | Codesystem |
|---|
| 252465000 : 405813007 = 56459004 | Pulse oximetry (procedure) : Procedure site - Direct (attribute) = Foot structure (body structure) | SNOMED Clinical Terms |
FHIR®-Mapping:
- KBV_PR_MIO_CMR_Composition_Pulse_Oxymetry_Screening
- KBV_PR_MIO_CMR_Diagnostic_Report_U1_U3_Pulse_Oxymetry
keine Neugeborenenpulsoxymetrie
...
| Code | BEZEICHNUNG IM CODESYSTEM | Codesystem |
|---|---|---|
| 428119001 : { 363589002 = 250554003 , 408730004 = 410534003 } | Procedure not indicated (situation) : { Associated procedure (attribute) = Measurement of oxygen saturation at periphery (procedure) , Procedure context (attribute) = Not indicated (qualifier value) } | SNOMED Clinical Terms |
FHIR®-Mapping: KBV_PR_MIO_CMR_Observation_U1_U3_Pulse_Oxymetry_Measurement.dataAbsentReason
Wert: Boolean
Eltern wünschen keine Pulsoxymetrie
...
| Code | BEZEICHNUNG IM CODESYSTEM | Codesystem |
|---|---|---|
| 183948000:363589002= 250554003252465000 | Refused procedure - parent's wish (situation) : Associated procedure (attribute) = Measurement of oxygen saturation at periphery Pulse Oximetry (procedure) | SNOMED Clinical Terms |
FHIR®-Mapping: KBV_PR_MIO_CMR_Observation_U1_U3_Pulse_Oxymetry_Measurement.dataAbsentReason
Wert: Boolean
Pulsoxymetrieuntersuchung
...
| Code | BEZEICHNUNG IM CODESYSTEM | Codesystem | ||
|---|---|---|---|---|
| 252465000 | Pulse oximetry | 250554003 | Measurement of oxygen saturation at periphery (procedure) | SNOMED Clinical Terms |
FHIR®-Mapping: KBV_PR_MIO_CMR_Observation_U1_U3_Pulse_Oxymetry_Measurement
Termin Pulsoxymetrie
Entsprechend der Papiervorlage ist die Dokumentation von Datum und Uhrzeit ermöglicht.
FHIR®-Mapping: KBV_PR_MIO_CMR_Observation_U1_U3_Pulse_Oxymetry_Measurement.effective[x]:effectiveDateTime
Wert: Datum/Zeit (mindestens Tag (TT), Monat (MM) und Jahr (JJJJ), Stunde (ss) und Minute (mm))
...
Angabe, ob es sich um die Erstmessung oder Kontrollmessung handelt.
FHIR®-Mapping: KBV_PR_MIO_CMR_Observation_U1_U3_Pulse_Oxymetry_Measurement.code
Wert: Code
| KONZEPT & WIEDERGABENAME | Code | BEZEICHNUNG IM CODESYSTEM | Codesystem |
|---|---|---|---|
| Erstmessung | 250554003 : 363703001 = 399455000 | Measurement of oxygen saturation at periphery (procedure) : Has intent (attribute) = Primary procedure (qualifier value) | SNOMED Clinical Terms |
| Kontrollmessung | 250554003 : 363703001 = 262134003 | Measurement of oxygen saturation at periphery (procedure) : Has intent (attribute) = Secondary procedure (qualifier value) | SNOMED Clinical Terms |
...
Beschreibung: Die Pulsoxymetrie erfolgt am Fuß.
Terminologie Assoziation:
| Code | BEZEICHNUNG IM CODESYSTEM | Codesystem |
|---|---|---|
| 59408-5 | Oxygen saturation in Arterial blood by Pulse oximetry | Logical Observation Identifier Names and Codes |
| 431314004 | Peripheral oxygen saturation (observable entity) | SNOMED Clinical Terms |
FHIR®-Mapping: KBV_PR_MIO_CMR_Observation_U1_U3_Pulse_Oxymetry_Measurement.value
Wert: Quantität (Einheit % (0-100))
...
| Code | BEZEICHNUNG IM CODESYSTEM | Codesystem |
|---|---|---|
| 447755005 | Finding of oxygen saturation (finding) | SNOMED Clinical Terms |
FHIR®-Mapping: KBV_PR_MIO_CMR_Observation_U1_U3_Pulse_Oxymetry_Measurement.interpretation
Wert: Code
| KONZEPT & WIEDERGABENAME | Code | BEZEICHNUNG IM CODESYSTEM | Codesystem |
|---|---|---|---|
| auffällig | 449171008 | Oxygen saturation below reference range (finding) | SNOMED Clinical Terms |
| unauffällig | 448225001 | Oxygen saturation within reference range (finding) | SNOMED Clinical Terms |
...
| Code | BEZEICHNUNG IM CODESYSTEM | Codesystem |
|---|---|---|
| 129125009 : { 363589002 = 250554003 , 408730004 = 385643006 , 408732007 = 410604004 } | Procedure with explicit context (situation) : { Associated procedure (attribute) = Measurement of oxygen saturation at periphery (prcedure) , Procedure context (attribute) = To be done (qualifier value) } | SNOMED Clinical Terms |
FHIR®-Mapping: KBV_PR_MIO_CMR_Observation_U1_U3_Pulse_Oxymetry_Measurement.interpretation
Wert: Boolean
kinderkardiolog. Abklärung veranlasst
...
| Code | BEZEICHNUNG IM CODESYSTEM | Codesystem |
|---|---|---|
| 417311009 | Referral to pediatric cardiology service (procedure) | SNOMED Clinical Terms |
FHIR®-Mapping:
- KBV_PR_MIO_CMR_Composition_Pulse_Oxymetry_Screening.section.entry
- KBV_PR_MIO_CMR_Service_ServiceRequestRequest_U1_U3_Pulse_Oxymetry_Clarification (Wenn ein ServiceRequest in der Composition referenziert wird, wurde eine Abklärung veranlasst.)
...
Text aus der Papierversion des U-Heftes: Abklärung veranlasst:
FHIR®-Mapping: KBV_PR_MIO_CMR_Service_ServiceRequestRequest_U1_U3_Pulse_Oxymetry_Clarification (Wenn ein ServiceRequest in der Composition referenziert wird, wurde eine Abklärung veranlasst.)
...
Datum Veranlassung Abklärung
FHIR®-Mapping: KBV_PR_MIO_CMR_ServiceRequestService_Request_U1_U3_Pulse_Oxymetry_Clarification.authoredOn
Wert: Datum (mindestens Tag (TT), Monat (MM) und Jahr (JJJJ))
| Kommentierungsbutton | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
Kommentierungen
Issuereporter